Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9294041

- Product Categories
- Friendly Links
Information Name: | What debugging method centrifugal fan? |
Published: | 2013-03-18 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | The debugging methods centrifugal fan is a complicated device structure, the main air inlet damper, impeller, motor, outlet composition. In a different state, the effect of the centrifugal fan is not the same. Therefore, a different part of the operating conditions do not agree, the effect of the centrifugal fan will be affected. The the centrifugal fan debugging to the best condition, you can start from a number of aspects. Centrifugal fan allows full pressure start-up or step-down electric, but it should be noted that the full voltage starting current is approximately 5-7 times the rated current, voltage starting torque is proportional to the square of the voltage, when the lack of grid capacity should be used voltage starting. Centrifugal fan in the trial run, should carefully read the product manual, check the wiring method is consistent with the wiring diagram; should carefully check the operating voltage of the supply fan power is not required, the power is missing phase or in phase, with the electrical components whether the capacity to meet the requirements. , Commissioning no fewer than two people, one person to control power, one to observe the fan running, immediately stop inspection found anomalies; First check the correct direction of rotation; centrifugal fan starts running, you should immediately check the current balance of each phase operation , if it is not a normal phenomenon, whether the current exceeds the rated current; should stop check. Five minutes after the operation, down to check fan anomalies, confirm no abnormality and then start running. The test of the two-speed centrifugal fan, you should start low speed, check the direction of rotation is correct; must be the starting high-speed fan still and then start to prevent high-speed reverse rotation, causing damage to the switch tripped and motor. Foshan Sanhe Environmental Ventilation Equipment Co., Ltd. was founded in 2000, is a professional manufacturer of FRP corrosion resistant fan, plastic fan, FRP, PP mist purification tower the green ventilation equipment company; company formerly known as Guangzhou Sanhe Environmental ventilation equipment company to meet the needs of the business development, the company in 2009 from Guangzhou Panyu relocation to the Sanshui District, Foshan City, Datang Industrial Park, and renamed as Foshan Sanhe Environmental Ventilation Equipment Co., Ltd.. Foshan Sanhe Environmental Ventilation Equipment Co., Ltd. Tel :0757 -87,270,024 Mobile: 13318880325 Contact: Mr. Li Zaixiong Website: http://www.zgfengji.com/ Address: Foshan Sanshui District Datangpo Center Technology Park Hublot Road |
Admin>>>
You are the 5529 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen extraordinary network All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5529 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen extraordinary network All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility